Products
PRODUCTS DETAILS
Home > Products >
500 m³/h High Flow 65 m Head Copper Impellers Submersible Deep-Well Pump for Large-Scale Groundwater Extraction

500 m³/h High Flow 65 m Head Copper Impellers Submersible Deep-Well Pump for Large-Scale Groundwater Extraction

Detail Information
Rated Flow:
500 M³/h
Rated Head:
65 M
Pump Head Material:
Copper
Impeller Material:
Copper
Installation Type:
Vertical Submerged
Pumped Medium:
Clean Water
Highlight:

500 m³/h High Flow Submersible Deep-Well Pump

,

65 m Head Deep Well Submersible Pump

,

Copper Impellers Borehole Submersible Pump

Product Description
Product Overview

The 300QJH500-65 submersible deep-well pump is engineered for high-capacity groundwater extraction and large-scale clean-water delivery. Its rated operating point is 500 m³/h at 65 m head. The hydraulic section features a copper pump head and copper impellers, while stainless steel is used for the specified pump components.

This material configuration is suitable for water-supply projects that require high flow, reliable submerged operation, and carefully selected water-contact materials.

Main Specifications
Parameter Specification
Model300QJH500-65
Pump typeSubmersible deep-well pump
Rated flow500 m³/h
Rated head65 m
Pump head materialCopper
Impeller materialCopper
Other specified componentsStainless steel
InstallationVertical submerged installation
Pumped mediumClean water within approved limits

The exact motor power, number of stages, stainless steel grade, copper grade or alloy, outlet size, voltage, frequency, and cable length should be stated in the technical quotation.

500 m³/h High-Flow Performance

At the rated operating point, the pump can deliver approximately:

  • 500 cubic metres per hour
  • 8.33 cubic metres per minute
  • 138.9 litres per second
  • 500,000 litres per hour

This capacity makes the pump suitable for projects where smaller deep-well pumps cannot provide enough water.

Actual flow depends on the total system head, well yield, pipeline diameter, delivery distance, and required outlet pressure. The manufacturer's performance curve should be checked before the model is approved.

Understanding the 65 m Head

The rated head of 65 m must cover all resistance in the water-delivery system, including:

  • Dynamic water level
  • Elevation from the wellhead to the discharge point
  • Friction loss in the rising pipe
  • Resistance in horizontal pipelines
  • Losses through valves, bends, and fittings
  • Required pressure at the final outlet

The 65 m head does not mean that the pump must be installed exactly 65 m deep. Pump installation depth is mainly determined by the dynamic water level, required submergence, and well construction.

Copper Pump Head and Impellers

The pump uses a copper pump head and copper impellers in its hydraulic section. The precise copper grade or copper alloy should be confirmed, because material performance depends on its chemical composition and the actual water conditions.

Before ordering, buyers should provide a water analysis containing:

  • pH value
  • Chloride concentration
  • Salinity
  • Dissolved solids
  • Sand content
  • Water temperature
  • Corrosive chemicals

Copper materials should not automatically be considered suitable for every corrosive liquid. Water chemistry and material compatibility must be reviewed for each project.

Stainless Steel Construction

The specified stainless steel components provide durable submerged construction and improved resistance to rust in suitable clean-water conditions.

The quotation should clearly state which components are stainless steel and identify the material grade — such as the pump shaft, motor shell, coupling, inlet section, or other water-contact parts. Buyers should not rely only on the general description "stainless steel pump."

Suitable Applications

The 300QJH500-65 can be considered for:

  • Large-scale groundwater extraction
  • Municipal and rural water supply
  • Agricultural irrigation
  • Reservoir and storage-tank filling
  • Industrial clean-water transfer
  • Cooling-water supply
  • Water-treatment plant intake
  • Long-distance water delivery
  • Centralized livestock water supply
  • Large commercial water systems

This model is intended for clean water. It should not be used for sewage, sludge, fibres, or water containing large solid particles.

Well Requirements

A pump with a rated flow of 500 m³/h requires a well with sufficient sustainable yield. The well should undergo a pumping test before the pump is selected.

Buyers should confirm:

  • Well depth
  • Internal casing diameter
  • Static water level
  • Dynamic water level
  • Sustainable well yield
  • Well straightness
  • Sand content
  • Distance from the pump to the well bottom

The pump should be installed below the lowest expected dynamic water level and above the sediment zone. The actual pump outside diameter must be checked against the internal casing diameter along the complete installation path.

Pipeline Requirements

The rising pipe and external delivery pipeline must be sized for the required 500 m³/h flow. An undersized pipe can create excessive friction loss, reduce the delivered flow, and increase operating costs.

The pipeline design should consider:

  • Internal pipe diameter
  • Working pressure
  • Maximum possible system pressure
  • Pipe length
  • Flow velocity
  • Non-return valve
  • Isolation valve
  • Pipe and wellhead load capacity

The supplier should provide the maximum or shut-off head so that the complete discharge system can be designed safely.

Motor and Control Protection

The motor power has not been specified and should be confirmed from the final hydraulic design. The control system should include:

  • Overload protection
  • Short-circuit protection
  • Phase-loss and phase-sequence protection
  • Abnormal-voltage protection
  • Dry-running protection
  • Low-water-level protection
  • Motor-temperature monitoring when available

The operating voltage, frequency, starting method, cable cross-section, and cable length must be matched to the installation site.

Documents Buyers Should Request

A complete technical offer should include:

  • Pump performance curve
  • Rated efficiency
  • Motor power and efficiency
  • Rated voltage, frequency, and current
  • Pump dimensions and total weight
  • Outlet size and connection standard
  • Number of hydraulic stages
  • Pump outside diameter
  • Copper material grade
  • Stainless steel material grade
  • Maximum permitted sand content
  • Maximum water temperature
  • Installation drawing
  • Cable specification
  • Spare-parts list
Information Required for a Quotation

Please provide:

  1. Required flow and total head
  2. Well depth and internal diameter
  3. Static and dynamic water levels
  4. Tested well yield
  5. Pipeline length and diameter
  6. Required terminal pressure
  7. Water analysis
  8. Site voltage and frequency
  9. Required cable length
  10. Required quantity
  11. Required material grades
  12. Inspection or certification requirements
Frequently Asked Questions
Is 500 m³/h the maximum flow?

It is the rated flow indicated by the model. The actual operating range and maximum flow must be confirmed from the pump performance curve.

Does 65 m head equal the well depth?

No. Total head includes the dynamic water level, delivery elevation, pipeline losses, and required outlet pressure.

Are both the pump head and impellers made of copper?

Yes. The specified configuration uses a copper pump head and copper impellers. The exact copper grade or alloy should be stated in the technical agreement.

Is the complete pump made of stainless steel?

The supplied information identifies the product as a stainless steel submersible deep-well pump with a copper pump head and copper impellers. The supplier should list the material of every main component to avoid misunderstanding.

Can it handle seawater?

Material suitability cannot be confirmed from the model alone. A water analysis and the exact copper and stainless steel grades are required for saline or high-chloride water.

Can it pump sewage?

No. This deep-well pump is intended for clean water and should not be used for sewage, sludge, fibres, or large solids.

Request a Technical Quotation

Send your well data, pipeline conditions, water analysis, and electrical requirements to confirm whether the 300QJH500-65 matches your project. The quotation should clearly specify the performance curve, motor power, material grades, dimensions, cable, and included accessories.

Products
PRODUCTS DETAILS
500 m³/h High Flow 65 m Head Copper Impellers Submersible Deep-Well Pump for Large-Scale Groundwater Extraction
Detail Information
Rated Flow:
500 M³/h
Rated Head:
65 M
Pump Head Material:
Copper
Impeller Material:
Copper
Installation Type:
Vertical Submerged
Pumped Medium:
Clean Water
Highlight

500 m³/h High Flow Submersible Deep-Well Pump

,

65 m Head Deep Well Submersible Pump

,

Copper Impellers Borehole Submersible Pump

Product Description
Product Overview

The 300QJH500-65 submersible deep-well pump is engineered for high-capacity groundwater extraction and large-scale clean-water delivery. Its rated operating point is 500 m³/h at 65 m head. The hydraulic section features a copper pump head and copper impellers, while stainless steel is used for the specified pump components.

This material configuration is suitable for water-supply projects that require high flow, reliable submerged operation, and carefully selected water-contact materials.

Main Specifications
Parameter Specification
Model300QJH500-65
Pump typeSubmersible deep-well pump
Rated flow500 m³/h
Rated head65 m
Pump head materialCopper
Impeller materialCopper
Other specified componentsStainless steel
InstallationVertical submerged installation
Pumped mediumClean water within approved limits

The exact motor power, number of stages, stainless steel grade, copper grade or alloy, outlet size, voltage, frequency, and cable length should be stated in the technical quotation.

500 m³/h High-Flow Performance

At the rated operating point, the pump can deliver approximately:

  • 500 cubic metres per hour
  • 8.33 cubic metres per minute
  • 138.9 litres per second
  • 500,000 litres per hour

This capacity makes the pump suitable for projects where smaller deep-well pumps cannot provide enough water.

Actual flow depends on the total system head, well yield, pipeline diameter, delivery distance, and required outlet pressure. The manufacturer's performance curve should be checked before the model is approved.

Understanding the 65 m Head

The rated head of 65 m must cover all resistance in the water-delivery system, including:

  • Dynamic water level
  • Elevation from the wellhead to the discharge point
  • Friction loss in the rising pipe
  • Resistance in horizontal pipelines
  • Losses through valves, bends, and fittings
  • Required pressure at the final outlet

The 65 m head does not mean that the pump must be installed exactly 65 m deep. Pump installation depth is mainly determined by the dynamic water level, required submergence, and well construction.

Copper Pump Head and Impellers

The pump uses a copper pump head and copper impellers in its hydraulic section. The precise copper grade or copper alloy should be confirmed, because material performance depends on its chemical composition and the actual water conditions.

Before ordering, buyers should provide a water analysis containing:

  • pH value
  • Chloride concentration
  • Salinity
  • Dissolved solids
  • Sand content
  • Water temperature
  • Corrosive chemicals

Copper materials should not automatically be considered suitable for every corrosive liquid. Water chemistry and material compatibility must be reviewed for each project.

Stainless Steel Construction

The specified stainless steel components provide durable submerged construction and improved resistance to rust in suitable clean-water conditions.

The quotation should clearly state which components are stainless steel and identify the material grade — such as the pump shaft, motor shell, coupling, inlet section, or other water-contact parts. Buyers should not rely only on the general description "stainless steel pump."

Suitable Applications

The 300QJH500-65 can be considered for:

  • Large-scale groundwater extraction
  • Municipal and rural water supply
  • Agricultural irrigation
  • Reservoir and storage-tank filling
  • Industrial clean-water transfer
  • Cooling-water supply
  • Water-treatment plant intake
  • Long-distance water delivery
  • Centralized livestock water supply
  • Large commercial water systems

This model is intended for clean water. It should not be used for sewage, sludge, fibres, or water containing large solid particles.

Well Requirements

A pump with a rated flow of 500 m³/h requires a well with sufficient sustainable yield. The well should undergo a pumping test before the pump is selected.

Buyers should confirm:

  • Well depth
  • Internal casing diameter
  • Static water level
  • Dynamic water level
  • Sustainable well yield
  • Well straightness
  • Sand content
  • Distance from the pump to the well bottom

The pump should be installed below the lowest expected dynamic water level and above the sediment zone. The actual pump outside diameter must be checked against the internal casing diameter along the complete installation path.

Pipeline Requirements

The rising pipe and external delivery pipeline must be sized for the required 500 m³/h flow. An undersized pipe can create excessive friction loss, reduce the delivered flow, and increase operating costs.

The pipeline design should consider:

  • Internal pipe diameter
  • Working pressure
  • Maximum possible system pressure
  • Pipe length
  • Flow velocity
  • Non-return valve
  • Isolation valve
  • Pipe and wellhead load capacity

The supplier should provide the maximum or shut-off head so that the complete discharge system can be designed safely.

Motor and Control Protection

The motor power has not been specified and should be confirmed from the final hydraulic design. The control system should include:

  • Overload protection
  • Short-circuit protection
  • Phase-loss and phase-sequence protection
  • Abnormal-voltage protection
  • Dry-running protection
  • Low-water-level protection
  • Motor-temperature monitoring when available

The operating voltage, frequency, starting method, cable cross-section, and cable length must be matched to the installation site.

Documents Buyers Should Request

A complete technical offer should include:

  • Pump performance curve
  • Rated efficiency
  • Motor power and efficiency
  • Rated voltage, frequency, and current
  • Pump dimensions and total weight
  • Outlet size and connection standard
  • Number of hydraulic stages
  • Pump outside diameter
  • Copper material grade
  • Stainless steel material grade
  • Maximum permitted sand content
  • Maximum water temperature
  • Installation drawing
  • Cable specification
  • Spare-parts list
Information Required for a Quotation

Please provide:

  1. Required flow and total head
  2. Well depth and internal diameter
  3. Static and dynamic water levels
  4. Tested well yield
  5. Pipeline length and diameter
  6. Required terminal pressure
  7. Water analysis
  8. Site voltage and frequency
  9. Required cable length
  10. Required quantity
  11. Required material grades
  12. Inspection or certification requirements
Frequently Asked Questions
Is 500 m³/h the maximum flow?

It is the rated flow indicated by the model. The actual operating range and maximum flow must be confirmed from the pump performance curve.

Does 65 m head equal the well depth?

No. Total head includes the dynamic water level, delivery elevation, pipeline losses, and required outlet pressure.

Are both the pump head and impellers made of copper?

Yes. The specified configuration uses a copper pump head and copper impellers. The exact copper grade or alloy should be stated in the technical agreement.

Is the complete pump made of stainless steel?

The supplied information identifies the product as a stainless steel submersible deep-well pump with a copper pump head and copper impellers. The supplier should list the material of every main component to avoid misunderstanding.

Can it handle seawater?

Material suitability cannot be confirmed from the model alone. A water analysis and the exact copper and stainless steel grades are required for saline or high-chloride water.

Can it pump sewage?

No. This deep-well pump is intended for clean water and should not be used for sewage, sludge, fibres, or large solids.

Request a Technical Quotation